Many customers may encounter situations where the cryogenic deflashing machine fails to operate properly during its operation due to environmental factors or operational errors. When seeking after-sales support, they may not be able to identify the root cause, leading to inadvertent triggering, system and structural changes, and irreversible consequences. This article is intended to address the troubleshooting of the frozen edger in non-damaged situations.

 

Symptoms

Possible Causes

Methods

1. Media not be ejected

 Insufficient amount of medias

 Confirm the quantity of Medias

 Medias are wet or frozen

 Replace the drying Medias

 Media feed tube interface in the media bin is blocked by burrs

 Clear clogging of burrs at the media conveying   pipe interface.

 Media feed tube is blocked by burrs

 Clear clogging of burrs inside the conveying pipe through.

 Media intake tube of the wheel is blocked by burrs

 Remove the fixed bolts inside the suction pipe of the wheel,   and clean out the burrs. Note: Do not displace the deflector

 vibrating separator is blocked by burrs

 Remove the clogging burrs from the vibrating screen.

 Damaged connection in the conveying pipeline causing media   leakage

 Replace the new pipeline

2.Projectile  wheel not rotate

 The door of working compartment is not completely closed

 Close the door of the working compartment completely.

 The engine bearing is burnt out

 Identify the cause of the burnt-out bearing and replace the   motor bearing with a new one.

3. Barrel not rotate

 The connector between the barrel rotating shaft and the motor   is damaged

 Identify the cause of the damage and replace the new   umbrella gear connector.

 The barrel drive device is also damaged

 Identify the cause of the damage and replace the new drive   device and other items.

4.Temperature inside the work chamber cannot decrease

 No supply of liquid nitrogen

 Check if the main valve of the tank is open, if the pipeline   valves are open, and if the vent valve is closed. Check if   there is enough liquid nitrogen in the tank, and if the supply   pressure is between 0.5~0.7Mpa.

Liquid nitrogen nozzle is blocked

Remove nozzle & Clear foreign objects

Electromagnetic valve for liquid nitrogen injection is malfunctioning

Replace the electromagnetic valve.

5.Abnormal vibration in the wheel rotation

Damage to motor bearings and other parts

Replace the damaged parts of the motor